Dynamic Testing Consultants

ContentsOur frontdoorOur products and servicesWhat's newRelated linksWelcome!


Hot Tack Tester 52-E/201

Contents:


The new DTC Hot Tack 52-E/201

The apparatus is designed for accurate testing of the mechanical properties of seals immediately after the heat sealing operation.

It is used for testing of both laminates, films, and coated paper and carton. It can also be used for testing seals in the cold state, for testing of adhesive tapes, etc. For the mechanical actions of the apparatus,pneumatic components are used, while the control and measurement functions are accomplished by a computer (PC).

The PC is part of the supply. Operating system is MicroSoft XP Pro. The test software is DTC´s Wintack program package.

Folding and insertion of the specimen is done by an automatic device. The specimen grips are pneumatic clamps with foot pedal control.

Manual sealing and manual peeling controls also possible.

 

 


Features

The DTC Hot Tack 52-E/201 allows the precise setting of following parameters:


Benefits

The Wintack software for Hot Tack testing is menu driven, and it is very easy to work with. When in the main menu, the operator selects the parameters, test identifications, file names, etc.
In the test menu, there is a choice of different types of Hot Tack tests, and routines for batch testing, testresult acceptance, etc.
After the end of a batch the operator may review the test results, edit them, and run tables and graphic presentation of the batch. From individual tests, Hot Tack - force vs. time or seal pressure vs. time can be displayed graphically on the screen and copied to the printer.

The whole system is designed and built to high accuracy standards. With each individual test the computer checks also the actually achieved parameters and reports these. In the software, there are routines for check-out, calibration, a.s.o. which enables the owner to maintain the system.


Specifications

Specifications for Hot Tack Tester 52-E/201

Sealing temperature: Hot Tack Force:
Range 50 - 400 oC 2 ranges 0 -10,00 N and 0 -100,0 N
Accuracy of measurement:  
± 2 oC Measuring accuracy in each range:
Setting accuracy: <± 0,5 % of range
± 1 digit  
  Specimen width:
Sealing force: 15-25 mm with standard grips
Range 10 - 250 N nominal  
Control accuracy, average force: Sealing bar width:
<± 5 % of setting value or 2 % of range 5 mm (standard)
   
Measuring accuracy: Power requirements:
± 1 % of average value 230 V AC, single phase, 50-60 Hz, 800 VA
   
Sealing time: Air supply:
Range 0,2 - 20 s Dry, clean compressed air, min 5 bar,
Control accurracy: max 8 bar
± 5 % of set value or ± 0,05 s, whichever is greater Flow capacity: 200 Nl/min.
Measuring accuracy: Shipping weight:
± 2 % of achieved value Approx 60 kg net
  Approx 80 kg gross
Delay time: Options:
(= time from end of seal to start of peel) · Impulse sealing bars with pulse generator
range 0,1- 20 s · Sealing bars of special width
Control accurracy:  · Step-up transformer 115 / 230 V AC
± 5 % of set value or ± 0,05 s whichever is greater · PC peripherals (monitor, printer, etc.).
Measuring accuracy :  
± 2 % of achieved value  
   
Peel speed: Related equipment:
Range: 30 - 300 mm/s nominal Specimen cutter model SC-199
Control accurracy:  
± 3 % of range  
Measuring accuracy of achieved speed:  
± 2 % of achieved value  

Back to Top


ContentsOur frontdoorOur products and servicesWhat's newRelated linksWelcome!

Copyright ©
Dynamic Testing Consultants.
All rights reserved.